Click here for the V6 Syringe Pump
Click here for the V6 Syringe Product Line

V6 Syringe Pump

The VersaPump 6 is a programmable precision fluid control device. It utilizes a non-volatile user program memory and system input/output (I/O). The V6 is designed with the flexibility and versatility to meet a variety of system configurations. It can be used as a stand alone controller, or integrated into system configurations. The module is capable of simple closed loop control of an external quantity or process without the need of an external controller for direction.

Mechanically, the syringe pump is driven via stepper motor and precision ball screw. It has a 60mm stroke and is available in three resolutions. The pump can be coupled with a variety of valves and syringes, as well as PC board selections, to meet specific needs. Pump communications are compatible with other Kloehn devices.


Physical
• Height 10”
• Width 2.55”
• Depth 4.75” (face plate to back plate) 4.9” to card edge
• Weight 5.14 lbs

Environmental
• Operating temperature of 0 to 50 C
• Operating humidity of 5 to 95% RH, non-condensing at 50 C
• Storage temperature of –25C to 85 C
• RoHS & WEEE compliant

Mechanical
• Operation in any orientation
• Mounting holes at top and bottom as well as on the face plate
• Resolutions available (12000; 24000; and 48000 increments)
• Speed; (Max. - 10000 steps / sec.; min. 60 steps / sec.) (Default - 5000 steps / sec.)
• Syringe size - 25ul to 50ml
• Valve type – 2 way to 12 way
• 3 PC board choices:
– Base board (sensor array and motor pin out only - no motor drivers or control electronics).
– Driver board (sensor array and motor drivers only, no control electronics).
– Driver & Control boards (fully functional motor drivers and control electronics).
• Card-edge connector
• Integrated RS232 Integrated power filter
• Multiple valve choices, including no valve & solenoid valve

1/10 Stroke Dispenses Full Stroke Dispenses
Precision: 0.10% CV, 0.20% max. 0.007% CV, 0.0092% max.
Accuracy: 0.20% CV, 0.60% max. --------


Interface
• RS-485 or RS-232 communications
• Data terminal or OEM protocol
• 1200 to 38.4K baud, 8 data bits, 1 stop bit, no parity, half duplex
• Three inputs, three output ports
• Digital voltmeter
• Switched and wired device address

Power
• Operation at 24V (with a maximum power voltage ripple of 720mv peak-to-peak) Power consumption – 40 watts, 11 watts idle.

Syringe Pump:

RESOLUTION VALVE FEATURE DRIVER & CONTROL FEATURE PUMP PT# DECAL PT#
48K 24K 12K NONE SOLE-
NOID
ROTARY BASIC DRIVER
BOARD
DRIVER &
CONTROL BOARD
X X X 54000 23279
X X X 54001 23279
X X X 55002 23279
X X X 54010 23279
X X X 54011 23279
X X X 55012 23279
X X X 54020 23279
X X X 54021 23279
X X X 55022 23279
X X X 54100 23279
X X X 54101 23279
X X X 55102 23279
X X X 54110 23279
X X X 54111 23279
X X X 55112 23279
X X X 54120 23279
X X X 54121 23279
X X X 55122 23279
X X X 54200 23279
X X X 54201 23279
X X X 55202 23279
X X X 54210 23279
X X X 54211 23279
X X X 55212 23279
X X X 54220 23279
X X X 54221 23279
X X X 55222 23279

Decal is optional, add to order as required. 3-way solenoid valve supplied with pumps configured for solenoid valve.

Precision Syringe Pump V6P:

RESOLUTION VALVE FEATURE DRIVER & CONTROL FEATURE PUMP PT# DECAL PT#
48K 24K ROTARY DRIVER & CONTROL BOARD
X X X 55023 23279
X X X 55123 23279


Ancillary items:

DESCRIPTION PART NUMBER
Communication cable RS485, 6” long; pump to pump (2 units) 17736 or 17736X
Cooling Fan 24290
Starter Kit (includes all items listed below) 23427
• 24VDC Power supply 23429
• Adapter (card edge to AMP connectors) 23428
• Connector (card edge with solder pins) 26875
• Software; operator’s manual; and application notes. 23422
• Communications cable (RS232 / 5’ long; pump to computer) 17734

Software support:
• KloehnControl (configuration and debug program)
• KSerial (command-line communication utility)
• KCom (machine language helper program)
• KProbe (communication trouble shooting utility)

Valves:

Configuration Orifice Distribution Non-Distribution Port Thread
Through mtg block 0.059 19218 ------ 1/4-28 UNF
2-WAY 0.059 ------ 1/4-28 UNF
3-WAY 0.059 17616 17615 1/4-28 UNF
4-WAY 0.059 17617 17712 1/4-28 UNF
5-WAY 0.059 17618 ------ 1/4-28 UNF
6-WAY 0.059 17619 ------ 1/4-28 UNF
8-WAY 0.059 17620 ------ 1/4-28 UNF
12-WAY 0.040 24105 ------ 1/4-28 UNF
3-WAY 0.076 18189 18192 1/4-28 UNF
4-WAY 0.076 18190 18191 1/4-28 UNF
5-WAY 0.076 18188 ------ 1/4-28 UNF
6-WAY 0.076 18193 ------ 1/4-28 UNF
8-WAY 0.076 17877 ------ 1/4-28 UNF

Valve construction:
• V6 pump uses the same valves as the 50300 pump
• Valve wetted surfaces have a Kel-F body insert and PTFE (Teflon) plug.
• Port connection is 1/4-28 UNF.
• Some valve ports may not be accessible when used with certain syringes sizes. See Application Notes for further information.

Standard Syringe Assembly (individually boxed):

Size Orifice Standard Syringe ZDV Port Thread
25ul 0.027 17591 ------ 1/4-28 UNF
50ul 0.024 17592 ------ 1/4-28 UNF
100ul 0.032 17593 ------ 1/4-28 UNF
250ul 0.039 17594 19509 1/4-28 UNF
500ul 0.076 17595 19538 1/4-28 UNF
1.0ml 0.076 17596 25429 1/4-28 UNF
1.25ml 0.076 17597 25431 1/4-28 UNF
2.5ml 0.076 17598 19539 1/4-28 UNF
5.0ml 0.076 17599 18463 1/4-28 UNF
10.0ml 0.076 17600 18469 1/4-28 UNF
25.0ml 0.076 17601 23734 1/4-28 UNF
50.0ml 0.076 17602 ------ 1/4-28 UNF

Syringe construction:
• Syringes have Borosilicate glass. The 25ul, 50ul, and 100ul syringes use a standard plunger tip, while the 250ul through 50ml incorporate a canted spring design.

UHMW Syringes (individually boxed):

Size Orifice Standard Syringe ZDV Port Thread
25ul 0.027 ------ ------ 1/4-28 UNF
50ul 0.024 24681 ------ 1/4-28 UNF
100ul 0.032 24518 ------ 1/4-28 UNF
250ul 0.039 19513 ------ 1/4-28 UNF
500ul 0.076 24694 25427 1/4-28 UNF
1.0ml 0.076 24690 25413 1/4-28 UNF
1.25ml 0.076 ------ 25438 1/4-28 UNF
2.5ml 0.076 24685 25388 1/4-28 UNF
5.0ml 0.076 18857 24691 1/4-28 UNF
10.0ml 0.076 19110 24139 1/4-28 UNF
25.0ml 0.076 24688 25380 1/4-28 UNF
50.0ml 0.076 ------ ------ 1/4-28 UNF

Syringe construction:
• Syringes have Borosilicate glass. The 25ul, 50ul, and 100ul syringes use a standard plunger tip, while the 250ul through 50ml incorporate a canted spring design.
• Wetted materials: Borosilicate glass; KEL-F; UHMW





V6 Syringe Product Line

The V6 syringe line is designed to couple to a Syringe V6 Pump and standard valve assembly. These syringes are typically used in various types of instruments and analyzers serving clinical, medical, and analytical instrumentation applications. An array of syringe volumes are available that can be dispensed and/or aspirated over a full 6cm stroke.

For additional custom modifications, see your Kloehn Sales Representative.

Physical
• Length (Dispensed): 4.370”
• Thread Type: 1/4-28 UNF-2A
• Test Pressure: 80 psi

Environmental
• Operating Temperature of 10 to 40°C
• Storage Temperature of -25 to 85°C
• Relative Humidity: Up to 100%

Mechanical


Syringe Sizes 10ul 25ul 50ul 100ul 250ul 500ul 1.0ml
Orifice Diameter (in) .016 .016 .024 .032 .039 .076 .076
Syringe Diameter (in) 0.4 0.4 0.4 0.4 0.4 0.4 0.4
*Max Drag Force (lbs) PTFE 3.0 3.0 3.0 3.0 3.0 3.0 3.0
UHMW 7.0 7.0 7.0 7.0 7.0 7.0 7.0

Syringe Sizes 1.25ml 2.5ml 5.0ml 10ml 25ml 50ml
Orifice Diameter (in) .076 .076 .076 .076 .076 .076
Syringe Diameter (in) 0.4 0.5 0.6 0.75 1.12 1.5
*Max Drag Force (lbs) PTFE 3.0 3.0 6.0 6.0 8.0 8.0
UHMW 7.0 7.0 10.0 10.0 15.0 15.0

* Add 1 pound drag force to non-lubricated plunger tip requests.

Chemical
• Standard Syringe Seal: PTFE
• Wetted Materials: Borosilicate Glass, Kel-F, PTFE (or UHMW) (smaller sizes ZDV tips are Teflon coated 316L)
• Syringe tips lubricated with laboratory-grade Silicone